Products / Rebar mesh

Rebar mesh

Welded reinforcing mesh in sheets or rolls. Mass per square metre follows from wire diameter and grid pitch; the table covers square grids.

Wire
3 to 12 mm
Pitch
50 to 200 mm
Example sheet
Confirm sheet dimensions with supplier
Standards
GOST 23279 · EN 10080 · ASTM A1064

The same grid can carry very different steel quantities.

Changing wire diameter from 6 to 8 mm adds 77.8% to nominal steel mass at the same spacing. Wire size, pitch and sheet dimensions all belong on the order.

Send the complete designation from your drawing with your quote request.

400 mm samplewire Ø6 · 200 mm centres400 mm sample
Ø6 at 200 centres2.22kg/m²
400 mm samplewire Ø8 · 200 mm centres400 mm sample
Ø8 at 200 centres3.95kg/m²

Nominal repeating-grid calculation at 7.85 g/cm³. Drawing is a grid detail; finite-sheet edge wires, overhangs and laps are excluded from the mass estimate.

Sizes and weights by standard

Weights are theoretical, from nominal dimensions at 7.85 g/cm³: Actual delivered mass and billing basis must be confirmed with the quotation. Verified tables have been checked against the stated standard or catalogue source; Calculated values are nominal estimates, subject to the stated assumptions.

All standards

Square mesh, kg per m²

Calculated

Each cell is kg per square metre for that wire (rows) and square pitch (columns): bar weight per metre × 2 ÷ pitch.

Calculated at 7.85 g/cm³, nominal wire diameter. Real sheets vary a few percent with overhang and weld.
kg/m² by wire and pitch
Wiremm50pitch, mm100pitch, mm150pitch, mm200pitch, mm
Ø32.221.110.7400.555
Ø43.951.971.320.986
Ø56.173.082.061.54
Ø68.884.442.962.22
Ø8–7.895.263.95
Ø10–12.38.226.17
Ø12–17.811.88.88
Nominal estimateRepeating grid; edge wires, overlaps and sheet overhangs alter finished-sheet mass
SupplyConfirm wire grade, actual sheet dimensions and applicable tolerances
EN 10080 · DIN 488

European mesh designations

In verification

European mesh schedules must specify wire grade, diameters, spacing and sheet dimensions. Australian SL/RL names are not EN or DIN designations.

We do not publish a figure we have not checked. Need this now? We source it per order: request a quote with the designation from your drawing.

ASTM A1064

Welded wire reinforcement

In verification

American designations like 6×6 W1.4/W1.4.

We do not publish a figure we have not checked. Need this now? We source it per order: request a quote with the designation from your drawing.

GOST 23279-85

CIS mesh designations

In verification

CIS mesh marks and the rebar grades that feed them (A240, A400, A500C).

We do not publish a figure we have not checked. Need this now? We source it per order: request a quote with the designation from your drawing.

Rebar grades

The bar or wire inside the mesh, across standards.

ClassGOSTENASTMGB
Smooth, 240 MPaA240 (A-I)–––
Ribbed, 400 MPaA400 (A-III)–A615 Gr60 (420)HRB400
Ribbed, 500 MPaA500CB500A / B500B–HRB500

Theoretical and delivered weight

Multiply the nominal table weight by the ordered length or area to estimate theoretical mass. Delivered mass can vary with manufacturing tolerances. Confirm whether the quotation and invoice use theoretical or weighed mass.

Need a size or standard not listed?

We hold no stock yard, so we are not limited to one. Send the designation from your drawing and we will source the welded reinforcing mesh to it.

REQUEST A QUOTE