Products / Rebar mesh
Rebar mesh
Welded reinforcing mesh in sheets or rolls. Mass per square metre follows from wire diameter and grid pitch; the table covers square grids.
- Wire
- 3 to 12 mm
- Pitch
- 50 to 200 mm
- Example sheet
- Confirm sheet dimensions with supplier
- Standards
- GOST 23279 · EN 10080 · ASTM A1064
The same grid can carry very different steel quantities.
Changing wire diameter from 6 to 8 mm adds 77.8% to nominal steel mass at the same spacing. Wire size, pitch and sheet dimensions all belong on the order.
Send the complete designation from your drawing with your quote request.
Nominal repeating-grid calculation at 7.85 g/cm³. Drawing is a grid detail; finite-sheet edge wires, overhangs and laps are excluded from the mass estimate.
Sizes and weights by standard
Weights are theoretical, from nominal dimensions at 7.85 g/cm³: Actual delivered mass and billing basis must be confirmed with the quotation. Verified tables have been checked against the stated standard or catalogue source; Calculated values are nominal estimates, subject to the stated assumptions.
All standardsSquare mesh, kg per m²
Calculated
Each cell is kg per square metre for that wire (rows) and square pitch (columns): bar weight per metre × 2 ÷ pitch.
| Wiremm | 50pitch, mm | 100pitch, mm | 150pitch, mm | 200pitch, mm |
|---|---|---|---|---|
| Ø3 | 2.22 | 1.11 | 0.740 | 0.555 |
| Ø4 | 3.95 | 1.97 | 1.32 | 0.986 |
| Ø5 | 6.17 | 3.08 | 2.06 | 1.54 |
| Ø6 | 8.88 | 4.44 | 2.96 | 2.22 |
| Ø8 | – | 7.89 | 5.26 | 3.95 |
| Ø10 | – | 12.3 | 8.22 | 6.17 |
| Ø12 | – | 17.8 | 11.8 | 8.88 |
EN 10080 · DIN 488European mesh designations
In verification
European mesh schedules must specify wire grade, diameters, spacing and sheet dimensions. Australian SL/RL names are not EN or DIN designations.
We do not publish a figure we have not checked. Need this now? We source it per order: request a quote with the designation from your drawing.
ASTM A1064Welded wire reinforcement
In verification
American designations like 6×6 W1.4/W1.4.
We do not publish a figure we have not checked. Need this now? We source it per order: request a quote with the designation from your drawing.
GOST 23279-85CIS mesh designations
In verification
CIS mesh marks and the rebar grades that feed them (A240, A400, A500C).
We do not publish a figure we have not checked. Need this now? We source it per order: request a quote with the designation from your drawing.
Rebar grades
The bar or wire inside the mesh, across standards.
| Class | GOST | EN | ASTM | GB |
|---|---|---|---|---|
| Smooth, 240 MPa | A240 (A-I) | – | – | – |
| Ribbed, 400 MPa | A400 (A-III) | – | A615 Gr60 (420) | HRB400 |
| Ribbed, 500 MPa | A500C | B500A / B500B | – | HRB500 |
Theoretical and delivered weight
Multiply the nominal table weight by the ordered length or area to estimate theoretical mass. Delivered mass can vary with manufacturing tolerances. Confirm whether the quotation and invoice use theoretical or weighed mass.
Need a size or standard not listed?
We hold no stock yard, so we are not limited to one. Send the designation from your drawing and we will source the welded reinforcing mesh to it.