Products / Sandwich panel, mineral wool core

Sandwich panel, mineral wool core

Steel-faced sandwich panels sourced to your project specification. Core type and thickness affect insulation; exact thermal, structural and fire performance must be confirmed for the selected product.

Thickness
50 to 200 mm
Core λ
≈ 0.040 W/m·K
Core density
≈ 100 kg/m³
Fire performance
Product-specific declaration

More core thickness. Less heat flow through the core.

At an assumed conductivity of 0.040 W/m·K, increasing core thickness by 50% lowers λ/thickness by one third. This comparison illustrates insulation thickness, not a declared panel U-value.

Send the complete designation from your drawing with your quote request.

core-only estimatecore 100 mm
100 mm core0.400W/m²K
core-only estimatecore 150 mm
150 mm core0.267W/m²K

Core thicknesses share a scale; steel facings are exaggerated. Whole-panel U-value, weight, fire rating and span limits require the selected manufacturer’s documents.

Sizes and weights by standard

Weights are theoretical, from nominal dimensions at 7.85 g/cm³: Actual delivered mass and billing basis must be confirmed with the quotation. Verified tables have been checked against the stated standard or catalogue source; Calculated values are nominal estimates, subject to the stated assumptions.

EN 14509

Core-only thermal estimate

Typical values

Illustrative core conductance λ ÷ thickness, using the conductivity assumed below. This is not a declared whole-panel U-value; facings, joints, surface resistances and installation also matter.

Assumed core conductivity for comparison: 0.040 W/m·K. Confirm the product’s declared value with the manufacturer.
Core-only U-value
ThicknessmmUW/m²K
500.80
600.67
800.50
1000.40
1200.33
1500.27
2000.20
Facings and coatingSpecified per manufacturer, product and exposure
Panel massRequires facing thicknesses, profiles, core density and overall thickness
Fire performanceReaction-to-fire class and fire resistance apply to a tested product/system; confirm its classification and installation conditions
EN 14509

Per-product performance

Product-specific

We supply to the specification required for your project. Panel mass, declared U-value, reaction to fire and load/span tables depend on the selected product, facings, joints and installation. Confirm these from the manufacturer’s Declaration of Performance and technical tables when quoting.

We do not publish a figure we have not checked. Need this now? We source it per order: request a quote with the designation from your drawing.